- Disconnect the 2P connectors from the radiator fan motor and condenser fan motor.
  
Terminal side of male terminals 
 
 
	- Test the motor by connecting battery power to the B terminal and ground to the A terminal.
 
	- If the motor fails to run or does not run smoothly, replace it.
 
 
 |   | 
Replace the thermostat if it is open at room temperature.
 To test a closed thermostat:
 
	- Suspend the thermostat (A) in a container of water. Do not let the thermometer (B) touch the bottom of the hot container.
 
 
 
 
	- Heat the water and check the temperature with a thermometer. Check the temperature at which the thermostat first opens and at which it is fully open.
 
	- Measure the lift height of the thermostat when it is fully open.
STANDARD THERMOSTAT 
| Lift height: | 
above 8.0 mm (0.31 in.) | 
 
| Starts opening: | 
76 - 80oC (169 – 176oF) | 
 
| Fully open: | 
90oC (194oF) | 
 
 
 
 
 |